About ADC
video introduction
~2.50 min. long
REFERENCES
ISO Cert
NSRRC 4 Meter EPU

http://www.nsrrc.org.tw/


Taiwan Photon Source (TPS) and its multidisciplinary experimental facilities is a 3.3 GeV electron energy, 518 meter circumference, low-emittance synchrotron storage ring which offer one of the world's brightest synchrotron x-ray sources, provide cutting-edge experimental facilities and novel multidisciplinary scientific research opportunities, enhance world-class academic research, as well as create Taiwan's scientific research marvels in the twenty-first century.

 

Undulator Type

EPU

Maximum Gap

³ 110 mm

Undulator Symmetry

Asymmetric

Length of Magnet Assemblies

3811.3 mm

Undulator Period

56.9 mm

Total Length of Undulator Including Space for Phase Change

3897 mm

Number of Full Size Poles

164

Permanent Magnet Material

NdFeB NEOMAX-38VH

Total Number of Poles

168

Remanence Used in the Design Calculations

1.22 T

 

ADC USA (ISO 9001 certified), located near Cornell University in Ithaca, New York, is a leading developer and supplier of complex scientific components and instruments for large government laboratories and corporations around the world. Founded as a privately held company in 1995, ADC has grown into one of world’s leading technology companies and has enjoyed 18 straight years of business growth and profitability with more than 500 customers located in over 26 countries. We have developed capabilities, design, procedures and training staff to provide “Turn-Key” Insertion Devices (Undulators) and Magnetic Measurement Systems complete with in-house and customer site training.